Where Innovation Meets Excellence In Saving Lives

How Our Training Structures Meet NFPA 1402 Standards

Facebook
LinkedIn
Reddit

NOTE: NFPA 1402 has been consolidated into NFPA 1400: Standard on Fire Service Training. For updated information on the standard, read our article here.

NFPA 1402: Standard on Facilities for Fire Training & Associated Props was updated in 2019; however, it previously detailed recommendations in a series of five guides – the first of which was published in 1985.

The process to write the newest document took three years, and involved the participation of firefighters, technical rescue specialists, manufacturers, engineers and architects – including two of Fire Training Structures’ (FTS) own experts.

In this blog, we’ll explain additions in the newest update and how our fire training structures and live fire props meet NFPA 1402 standards to protect trainee safety.

What Standards Does NFPA 1402 Update from Prior Versions?

A key difference in the 2019 update of NFPA 1402 is that many of its guidelines are now standards, instead of recommendations.

Here are the most significant updates:

  • Two chapters were added addressing gas-fueled live fire training systems
  • A chapter on smoke buildings was removed and replaced with a chapter addressing requirements for technical rescue training facilities
  • A chapter on fire investigation training facilities was added
  • An annex was added to further expand on ideas expressed inside the document
Fire covers the ceiling of an insulated burn room.
NFPA 1402 standards exist to provide guidelines for conducting fire fighter training effectively, efficiently and safely. This is especially important for burn rooms, which expose trainees to real-fire scenarios inside a controlled environment.

Do the Standards in NFPA 1402 Apply to your Department?

While the standards in NFPA 1402 may apply to your department, it depends on the authorities having jurisdiction. Consult county and state authorities to see if your department is subject to NFPA 1402 or another set of regulations.

Are the Standards of NFPA 1402 Retroactive?

The standards in NFPA 1402 are not necessarily retroactive. While debated, the technical committee agreed that making the standard retroactive would present a costly burden for smaller departments.

Standards in the document that are retroactive are specified within the document or utilize “shall” to indicate requirements.

This means most of the 2019 revisions don’t need to be applied to props constructed before the updates were instituted.

A multi-level fire training structure with railings, stairs, vents, lights and training doors.
When you work with FTS, you can rest assured that your training system will meet all NFPA 1402 standards, including those for railings, stairs and doors.

Do Our Training Structures Meet NFPA 1402 Standards?

With FTS’s chief engineer on the NFPA 1402 Technical Committee, we have a deep understanding of the document’s standards, and the intentions behind these standards. We designed our systems within these guidelines even before they were standardized.

Take our movable wall partitions for example. We understand how important it is for realistic fire training that these partitions don’t budge under pressure. That’s why our engineers designed these components to withstand repeated exposure to training water and impact forces, a key standard in NFPA 1402.

Our designs have firefighter safety at their core, which is why we ensure that our systems don’t only meet the standards outlined by this standard but exceed them.

What does that mean for your department? It means you can rest assured that when you purchase a training structure from us, your structure is guaranteed to meet NFPA 1402 standards and have mechanisms to protect trainees’.

One of FTS’s core values is protecting firefighters. That’s why we’re committed to building our structures without cutting corners or compromising the quality of our materials. Our fabricators know that every structure we make is helping shape the firefighters of tomorrow, so we take our work seriously.

In sum, FTS systems meet all the standards outlined in NFPA 1402, including handrail height requirements, stairs with 7” maximum rise and 11” minimum treads, doors that are operable from both sides and more.

An Arizona firefighter wearing gear makes his way up a ladder with a safety cage surrounding him.
According to both NFPA and OSHA standards, ladders over 20ft tall must have a safety cage installed to prevent falls and injuries.

Summary

NFPA 1402 is an excellent resource for those working with fire training facilities, customizing them or acquiring them.

For access to the entire guideline document, consult the National Fire Protection Association’s page on the standard. In 2026, this standard will be consolidated with six other standards into NFPA 1400, Standard on Fire Service Training.

If your department requires a structure for training that meets NFPA 1402 standards, FTS will provide the solution you need. For more information about how FTS systems meet these standards and how your department can benefit from stationary or portable training structures, contact us today. To read the complete standard, access it from NFPA’s official website.

Ready to elevate your firefighting with a state-of-the-art mobile training structure?

Don't wait – take the first step towards enhanced preparedness today! Click below to request your free quote for a customized fire training structure and equip your team with the tools they need to tackle any emergency with confidence.

GET A QUOTE